To
activate the Savior LPG Detector connects it to 230V AC/12V
DC and switch on the activation switch. If there is leakage
of LPG on Save Zone/ Danger- I Zone Savior LPG Detector
reaches a set operating point it sends a signal to programmed
microchip, then microchip sends a signal to the Audio Alarm
70 dB with Yellow LED indication and as prevention Automatic
Exhaust Fan will ON by sealed electromagnetic switch.
If there is leakage of LPG on Danger Zone/Danger-II Zone
Savior LPG Detector reaches a set operating point it sends
a signal to programmed microchip, then microchip sends a
signal to the Audio High dB Hooter Alarm with Visual Red
LED indication
The alarm sounds until the situation becomes normal/ by
switch off the activation switch. |